Regarding LandGlass flat&bent bi-directional glass tempering furnace, following steps should be concerned for the conversion procedure between flat & bent tempering:
1. At the adjusting interface of B bending, click “fault reset” and confirm “brake open” .
2. Click “select zero”.
3. Set 10 for “speed”, and 100 for “height”.
4. Click “bending start”. Normally the “height display” is 100.
5. Click “auto-level”. The “height display” is 0.